Verifier G3+ FLX Fault Finder Utility Locator

  • Pair your smartphone and access important information right at your fingertips
  • Plug and play design recognizes the A-frame for easy setup, enabling accurate and efficient fault location
  • Exclusive 3-year warranty and weatherproof guarantee
  • Locate multiple utilities and find faults for versatile jobsite applications

General

Manufacturer Vermeer
Model Verifier G3+ FLX Fault Finder Utility Locator
Category Utility Installation, Vacuum Excavation
Price Request a Quote
Year 2024

Receiver (RX)

Active frequencies 38 kHz ±2%, 9.5 kHz ±2%, 80 kHz ±2%, 850 Hz ±2%, 512 Hz ±2%, Fault finding (FF): 512 Hz and 9.5 kHz
Passive radio 9 kHz to 33 kHz (80 bands)
Passive power 50 Hz - 60 Hz, 100 Hz - 120 Hz
Battery Type Six alkaline LR6 AA
Battery life 18 hours, 68°F (20°C)
Battery status Continuous indication
Power save function Automatic power off after 6 minutes of inactivity
Visual indication LCD: bar graph, digital number and character
Depth display High-precision depth measurement
Range Line: 0 m to 5 m / 0 ft to 16 ft, 0 m to 10 m / 30 ft; Probe: 0 to 10 m / 30 ft; Real-time depth measurement: 0 m to 9.9 m / 0 ft to 33 ft
Depth readout unit Feet, meter and inch
Depth accuracy 6.5 ft (2 m): ±2.5%, 10 ft (3 m): ±5%, 16.5 ft (5 m): ±10%
Current value Current value showing on the conductor is displayed for line identity in milliamps (mA)
Audio output Internal speaker with volume adjustor
Data Transfer Via wireless 5.0 on Verifier® G3+ Locator Map app (available for iOS and Android)
Data logging Memorize 400 points of depth, current measurement, date and time
Interface 6-pin output connector
Operating temperature -4°F to 122°F (-20°C to 50°C)
Dimensions 26 in x 5.1 in x 10.6 in ( 66 cm x 13 cm x 27 cm)
Weight 4.7 lb (2.1 kg) including six alkaline batteries
Output frequencies 38 kHz ±2%, 9.5 kHz ±2%, 80 kHz ±2% (standard frequency); 9.5 kHz ±.02%, 80 kHz ±.02%, 512 Hz ±.02% (direct connection mode only); Dual: 9.5 kHz and 38 kHz ±.02% (direct connection mode only); Fault finder (FF): 512 Hz and 9.5 kHz ±.02%
Output power 7 watts maximum, 80 kHz: 1 watt maximum
Operating modes Direct connection mode, inductive mode and external coil clamp mode
Remote controlled transmitter Via wireless 5.0 on Verifier® G3+ Locator Map app (available for iOS and Android)
Battery Type Eight alkaline LR20 D or lithium-ion pack (optional)
Battery life (alkaline) Direct mode: 50 hours — output 4 mA, 8°F (20°C); Inductive mode: 20 hours — output 50%, 68°F (20°C); Full power (7 W): 10 hours, 68°F (20°C)
Battery life (lithium pack) Direct mode: 100 hours — output 4 mA, 68°F (20°C); Inductive mode: 40 hours — output 50%, 68°F (20°C); Full power (7 W): 20 hours, 68°F (20°C)
Battery status Low battery indication and press key readout
Visual indication LCD: bar graph and digital number
Audio indication Internal speaker: alarm and beeping sounds
Measuring function Output current: 0 mA - 500 mA, line voltage: 0 V - 250 V
Output protection AC 250 V, 512 Hz, output is cut off automatically
Weight 6.8 lb (3.1 kg) lithium-ion battery, 7.9 lb (3.5 kg) including eight alkaline batteries